Tick Rating


The Tick Rating is defined as follows:

Air-conditioners

Type
Minimum COP 100%1 (W / W)
No. of Ticks
0
1
2
3
4
Casement, window, single-split (non-inverter)
< 2.5
> 2.5
> 2.78
> 3.2
N/A
Multi-split (non-inverter)
< 2.64
> 2.64
> 2.92
> 3.34
N/A
Split type (inverter)2
  • COP100%
  • Weighted COP 3



N/A
< 2.64



N/A
> 2.64



N/A
> 2.92



>3.06
> 3.34



> 3.34
> 3.76


1
COP 100% is defined as the ratio of total cooling capacity to effective power input at full load cooling capacity
2 For split (inverter) type air-conditioners, the model shall meet both the minimum COP 100% and weighted COP
3 Weighted COP = 0.4 x COP 100% + 0.6 x COP 50%

Refrigerators

Type
Maximum Annual Energy Consumption (kWh)
No. of Ticks
0
1
2
3
4
Without freezer
> (368 + 0.892 x
Vadj tot4)
< (368 + 0.892 x Vadj tot)
< [(368 + 0.892 x
Vadj tot) x 0.86 ]
< [(368 + 0.892 x
Vadj tot) x 0.74]
< [(368 + 0.892 x
Vadj tot) x 0.64]
With freezer
> (465 + 1.378 x
Vadj tot)
< (465 + 1.378 x Vadj tot)
< [(465 + 1.378 x
Vadj tot) x 0.77]
< [(465 + 1.378 x
Vadj tot) x 0.593]
< [(465 + 1.378 x
Vadj tot) x 0.457]
With freezer ,
through-the -
door 5
> (585 + 1.378 x
Vadj tot)
< (585 + 1.378 x Vadj tot)
< [(585 + 1.378 x
Vadj tot) x 0.77]
< [(585 + 1.378 x
Vadj tot) x 0.593]
< [(585 + 1.378 x
Vadj tot) x 0.457]


4 Vadj tot is defined here

5 'Through-the-door ice dispenser' means an automatic ice maker coupled with a device that deliveries ice on demand externally through a door